Fluke 5606-50-B Full-Immersion PRT with Bare Wire

Model: 5606-50-B | UPC: 95969545181

Fluke 5606-50-B Full-Immersion PRT with Bare Wire-


Downloads: datasheet

Fluke 5606-50-B Full-Immersion PRT with Bare Wire

Model: 5606-50-B

This full-immersion PRT with bare wire is designed to perform in extreme temperatures where both the transition junction and the lead wires are required to withstand temperatures covering the entire operating range of the probe.

This full-immersion PRT with bare wire is designed to perform in extreme temperatures where both the transition junction and the lead wires are required to withstand temperatures covering the entire operating range of the probe.

Sale Price $411.30 USD
Regular Price $457.00 USD
Availability 2 to 3 Weeks
Quantity

Fluke 5606-50-B Offers

This full-immersion PRT has a calibration accuracy of ±0.05°C.

Features

  • -328 to 320°F (-200 to 160°C)
  • Transition junction and lead wires can withstand full PRT temperature range
  • Unique probe seal of 5606 prevents ingress of moisture
  • Calibration not included; NVLAP-accredited calibration optional

Fluke 5606-50-B Specifications

Temperature Range -328 to 320°F (-200 to 160°C)
Nominal Resistance At 0.01°C 100Ω ±0.1Ω
Temperature Coefficient 0.00385Ω/Ω/°C
Accuracy ±0.04 at 0.01°C; ±0.06 at 160°C
Short-Term Repeatability ±0.03 at 0.01°C; ±0.04 at 160°C
Drift ±0.03 at 0.01°C; ±0.04 at 160°C
Hysteresis ±0.015°C
Sheath Length 1.97in ±0.2in (50mm ±5mm)
Sheath Diameter 0.13in ±0.004in (3.1mm ±0.1mm)
Sheath Material 316 SST
Transition Junction Temperature Range -328 to 320°F (-200 to 160°C)
Sensor Length 1.2in ±0.1 in (30mm ±3mm)
Sensor Location 1.2in ±0.04in (3mm ±1mm from tip)
Minimum Insulation Resistance 20MΩ at 23°C
Minimum Immersion Length Full immersion
Maximum Immersion Depth In Liquid Medium Full immersion
Maximum Immersion Depth In Dry Medium Full immersion
Response Time 12 seconds typical
Self Heating (In 0°C Bath) ±0.003°C
Lead-Wire Cable Type Enameled copper wire
Lead-Wire Length 8ft (2.4m)
Lead-Wire Temperature Range 160°C
Calibration Calibration not included. NVLAP accredited calibration available. See ordering information
Click here for complete specifications on the Fluke 5606-50-B

What's included with the Fluke 5606-50-B

  • Fluke 5606-50-B Full-Immersion PRT with Bare Wire
  • Customer Reviews for the Fluke 5606-50-B

    Ask a question about Fluke 5606-50-B Full-Immersion PRT with Bare Wire

    Fluke 5606-50-B Offers

    This full-immersion PRT has a calibration accuracy of ±0.05°C.

    Features

    • -328 to 320°F (-200 to 160°C)
    • Transition junction and lead wires can withstand full PRT temperature range
    • Unique probe seal of 5606 prevents ingress of moisture
    • Calibration not included; NVLAP-accredited calibration optional

    Fluke 5606-50-B Specifications

    Temperature Range -328 to 320°F (-200 to 160°C)
    Nominal Resistance At 0.01°C 100Ω ±0.1Ω
    Temperature Coefficient 0.00385Ω/Ω/°C
    Accuracy ±0.04 at 0.01°C; ±0.06 at 160°C
    Short-Term Repeatability ±0.03 at 0.01°C; ±0.04 at 160°C
    Drift ±0.03 at 0.01°C; ±0.04 at 160°C
    Hysteresis ±0.015°C
    Sheath Length 1.97in ±0.2in (50mm ±5mm)
    Sheath Diameter 0.13in ±0.004in (3.1mm ±0.1mm)
    Sheath Material 316 SST
    Transition Junction Temperature Range -328 to 320°F (-200 to 160°C)
    Sensor Length 1.2in ±0.1 in (30mm ±3mm)
    Sensor Location 1.2in ±0.04in (3mm ±1mm from tip)
    Minimum Insulation Resistance 20MΩ at 23°C
    Minimum Immersion Length Full immersion
    Maximum Immersion Depth In Liquid Medium Full immersion
    Maximum Immersion Depth In Dry Medium Full immersion
    Response Time 12 seconds typical
    Self Heating (In 0°C Bath) ±0.003°C
    Lead-Wire Cable Type Enameled copper wire
    Lead-Wire Length 8ft (2.4m)
    Lead-Wire Temperature Range 160°C
    Calibration Calibration not included. NVLAP accredited calibration available. See ordering information
    Click here for complete specifications on the Fluke 5606-50-B

    What's included with the Fluke 5606-50-B

  • Fluke 5606-50-B Full-Immersion PRT with Bare Wire
  • Ask a question about Fluke 5606-50-B Full-Immersion PRT with Bare Wire

    Customer Reviews for the Fluke 5606-50-B

    More Fluke Products