Quickly get accurate measurements using this very stable secondary PRT, which features bare wire connections.
Quickly get accurate measurements using this very stable secondary PRT, which features bare wire connections.
Features
Temperature Range | -328 to 1,238°F (-200 to 670°C) |
Nominal Resistance at 0.01°C | 100Ω ±0.5Ω |
Temperature Coefficient | 0.0039250Ω/Ω/°C |
Short-Term Repeatability | ±0.01 at 0.010°C; ±0.02°C at max temp |
Drift | ±0.01 at 0.010°C; ±0.02°C at max temp |
Hysteresis | ±0.01°C maximum |
Sensor Length | 1.2in ±0.2in (30mm ±5mm) |
Sensor Location | 0.1in ±0.1in (3mm ±1mm from tip) |
Minimum Insulation Resistance | 500MΩ at 23°C, 10MΩ at 670°C |
Transition Junction Dimensions | 2.8 x 0.49in (71 x 12.5mm) |
Minimum Immersion Length (<5 mK Error) | 3.9in (100mm) |
Maximum Immersion Length | 12in (305mm) |
Response Time | 12 seconds typical |
Self Heating (In 0°C Bath) | 50mW/°C |
Lead-Wire Cable Type | Teflon, 24AWG |
Lead-Wire Length | 6ft (1.8m) |
Lead-Wire Temperature Range | -58 to 482°F (-50 to 250°C) |
Calibration | Calibration not included; NVLAP-accredited calibration optional, lab code 200348-0; please see calibration uncertainty table and its explanation of changeable uncertainties |
Click on a category to view a selection of compatible accessories with the Fluke 5609-20-B Secondary PRT with Bare Wire, 6ft Lead, Calibration Options.
Temperature Range | -328 to 1,238°F (-200 to 670°C) |
Nominal Resistance at 0.01°C | 100Ω ±0.5Ω |
Temperature Coefficient | 0.0039250Ω/Ω/°C |
Short-Term Repeatability | ±0.01 at 0.010°C; ±0.02°C at max temp |
Drift | ±0.01 at 0.010°C; ±0.02°C at max temp |
Hysteresis | ±0.01°C maximum |
Sensor Length | 1.2in ±0.2in (30mm ±5mm) |
Sensor Location | 0.1in ±0.1in (3mm ±1mm from tip) |
Minimum Insulation Resistance | 500MΩ at 23°C, 10MΩ at 670°C |
Transition Junction Dimensions | 2.8 x 0.49in (71 x 12.5mm) |
Minimum Immersion Length (<5 mK Error) | 3.9in (100mm) |
Maximum Immersion Length | 12in (305mm) |
Response Time | 12 seconds typical |
Self Heating (In 0°C Bath) | 50mW/°C |
Lead-Wire Cable Type | Teflon, 24AWG |
Lead-Wire Length | 6ft (1.8m) |
Lead-Wire Temperature Range | -58 to 482°F (-50 to 250°C) |
Calibration | Calibration not included; NVLAP-accredited calibration optional, lab code 200348-0; please see calibration uncertainty table and its explanation of changeable uncertainties |
Click on a category to view a selection of compatible accessories with the Fluke 5609-20-B Secondary PRT with Bare Wire, 6ft Lead, Calibration Options.