1-888-610-7664

sales@GlobalTestSupply.com

Chat Live

Customer Reviews

Fluke 5615-6-A Secondary Reference Temperature Standards with INFO-CON for 914X Models, 6 x 0.188in

Model: 5615-6-A | UPC: 95969420686

Fluke 5615-6-A Secondary Reference Temperature Standards with INFO-CON for 914X Models, 6 x 0.188in-

Fluke 5615-6-A Secondary Reference Temperature Standards with INFO-CON for 914X Models, 6 x 0.188in

Model: 5615-6-A

This Inconel-sheathed secondary reference temperature standard features a durable design thanks to its fully supported sensing element, which is surrounded in a ceramic case with a moisture- and contaminant-resistant hermetic glass seal. The temperature standard is ideal for use in the factory, field or lab and features INFO-CON connections for 914X models and 6 x 0.188in sizing.

This Inconel-sheathed secondary reference temperature standard features a durable design thanks to its fully supported sensing element, which is surrounded in a ceramic case with a moisture- and contaminant-resistant hermetic glass seal. The temperature standard is ideal for use in the factory, field or lab and features INFO-CON connections for 914X models and 6 x 0.188in sizing.

Your Price $1350.00 USD
Availability 3 to 4 Weeks
Quantity

Fluke 5615-6-A Offers

It bridges the gap between a 100Ω industrial RTD and an SPRT.

Features

  • Wide-range accuracy
  • Excellent stability
  • Reference-grade platinum sensing element
  • NVLAP-accredited calibration included, lab code 200706-0

Fluke 5615-6-A Specifications

Temperature Range -328 to 572°F (-200 to 300°C)
Nominal Resistance At 0°C 100Ω ±0.10Ω
Temperature Coefficient 0.0039250Ω/Ω/°C
Accuracy (Includes Calibration And 100-Hour Drift (k=2)) ±0.024°C at -200°C; ±0.012°C at 0°C; ±0.035°C at 420°C
Drift (After 100 Hours At Max Temp, 95% Confidence (k=2)) ±0.007°C at 0.010°C
Sensor Length 1.1in (28mm)
Sensor Location 0.27in ±0.13in (6.9mm ±3.3mm) from tip
Lead-Wire Cable Type PTFE insulated with PTFE jacket, 22AWG
Lead-Wire Length 6ft (183cm)
Calibration NVLAP-accredited calibration included, lab code 200706-0

What's included with the Fluke 5615-6-A

  • Fluke 5615-6-A Secondary Reference Temperature Standards with INFO-CON for 914X Models, 6 x 0.188in
  • Customer Reviews for the Fluke 5615-6-A

    Ask a question about Fluke 5615-6-A Secondary Reference Temperature Standards with INFO-CON for 914X Models, 6 x 0.188in

    Fluke 5615-6-A Offers

    It bridges the gap between a 100Ω industrial RTD and an SPRT.

    Features

    • Wide-range accuracy
    • Excellent stability
    • Reference-grade platinum sensing element
    • NVLAP-accredited calibration included, lab code 200706-0

    Fluke 5615-6-A Specifications

    Temperature Range -328 to 572°F (-200 to 300°C)
    Nominal Resistance At 0°C 100Ω ±0.10Ω
    Temperature Coefficient 0.0039250Ω/Ω/°C
    Accuracy (Includes Calibration And 100-Hour Drift (k=2)) ±0.024°C at -200°C; ±0.012°C at 0°C; ±0.035°C at 420°C
    Drift (After 100 Hours At Max Temp, 95% Confidence (k=2)) ±0.007°C at 0.010°C
    Sensor Length 1.1in (28mm)
    Sensor Location 0.27in ±0.13in (6.9mm ±3.3mm) from tip
    Lead-Wire Cable Type PTFE insulated with PTFE jacket, 22AWG
    Lead-Wire Length 6ft (183cm)
    Calibration NVLAP-accredited calibration included, lab code 200706-0

    What's included with the Fluke 5615-6-A

  • Fluke 5615-6-A Secondary Reference Temperature Standards with INFO-CON for 914X Models, 6 x 0.188in
  • Ask a question about Fluke 5615-6-A Secondary Reference Temperature Standards with INFO-CON for 914X Models, 6 x 0.188in

    Customer Reviews for the Fluke 5615-6-A

    More Fluke Products