1-888-610-7664

sales@GlobalTestSupply.com

Customer Reviews

Fluke 5615-9BND-B Secondary Reference Temperature Standards with Bare Wire, 9 x 0.188in, 90° Bend

Model: 5615-9BND-B | UPC: 095969794169

Fluke 5615-9BND-B Secondary Reference Temperature Standards with Bare Wire, 9 x 0.188in, 90° Bend-

Fluke 5615-9BND-B Secondary Reference Temperature Standards with Bare Wire, 9 x 0.188in, 90° Bend

Model: 5615-9BND-B

This Inconel-sheathed secondary reference temperature standard features a durable design thanks to its fully supported sensing element, which is surrounded in a ceramic case with a moisture- and contaminant-resistant hermetic glass seal. The 90°-bent temperature standard is ideal for use in the factory, field or lab and features bare wire connections and 9 x 0.188in sizing.

This Inconel-sheathed secondary reference temperature standard features a durable design thanks to its fully supported sensing element, which is surrounded in a ceramic case with a moisture- and contaminant-resistant hermetic glass seal. The 90°-bent temperature standard is ideal for use in the factory, field or lab and features bare wire connections and 9 x 0.188in sizing.

Your Price $1740.00 USD
Availability 2 to 3 Weeks
Quantity

Fluke 5615-9BND-B Offers

It bridges the gap between a 100Ω industrial RTD and an SPRT.

Features

  • Wide-range accuracy
  • Excellent stability
  • Reference-grade platinum sensing element
  • NVLAP-accredited calibration included, lab code 200706-0

Fluke 5615-9BND-B Specifications

Temperature Range -328 to 572°F (-200 to 300°C)
Nominal Resistance At 0°C 100Ω ±0.10Ω
Temperature Coefficient 0.0039250Ω/Ω/°C
Accuracy (Includes Calibration And 100-Hour Drift (k=2)) ±0.024°C at -200°C; ±0.012°C at 0°C; ±0.035°C at 420°C
Drift (After 100 Hours At Max Temp, 95% Confidence (k=2)) ±0.007°C at 0.010°C
Sensor Length 1.1in (28mm)
Sensor Location 0.27in ±0.13in (6.9mm ±3.3mm) from tip
Lead-Wire Cable Type PTFE insulated with PTFE jacket, 22AWG
Lead-Wire Length 6ft (183cm)
Calibration NVLAP-accredited calibration included, lab code 200706-0

What's included with the Fluke 5615-9BND-B

  • Fluke 5615-9BND-B Secondary Reference Temperature Standards with Bare Wire, 9 x 0.188in, 90° Bend

Click on a category to view a selection of compatible accessories with the Fluke 5615-9BND-B Secondary Reference Temperature Standards with Bare Wire, 9 x 0.188in, 90° Bend.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Ask a question about Fluke 5615-9BND-B Secondary Reference Temperature Standards with Bare Wire, 9 x 0.188in, 90° Bend

Customer Reviews for the Fluke 5615-9BND-B

Fluke 5615-9BND-B Offers

It bridges the gap between a 100Ω industrial RTD and an SPRT.

Features

  • Wide-range accuracy
  • Excellent stability
  • Reference-grade platinum sensing element
  • NVLAP-accredited calibration included, lab code 200706-0

Fluke 5615-9BND-B Specifications

Temperature Range -328 to 572°F (-200 to 300°C)
Nominal Resistance At 0°C 100Ω ±0.10Ω
Temperature Coefficient 0.0039250Ω/Ω/°C
Accuracy (Includes Calibration And 100-Hour Drift (k=2)) ±0.024°C at -200°C; ±0.012°C at 0°C; ±0.035°C at 420°C
Drift (After 100 Hours At Max Temp, 95% Confidence (k=2)) ±0.007°C at 0.010°C
Sensor Length 1.1in (28mm)
Sensor Location 0.27in ±0.13in (6.9mm ±3.3mm) from tip
Lead-Wire Cable Type PTFE insulated with PTFE jacket, 22AWG
Lead-Wire Length 6ft (183cm)
Calibration NVLAP-accredited calibration included, lab code 200706-0

What's included with the Fluke 5615-9BND-B

  • Fluke 5615-9BND-B Secondary Reference Temperature Standards with Bare Wire, 9 x 0.188in, 90° Bend

Click on a category to view a selection of compatible accessories with the Fluke 5615-9BND-B Secondary Reference Temperature Standards with Bare Wire, 9 x 0.188in, 90° Bend.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Ask a question about Fluke 5615-9BND-B Secondary Reference Temperature Standards with Bare Wire, 9 x 0.188in, 90° Bend

Customer Reviews for the Fluke 5615-9BND-B

More Fluke Products