Fluke 5615-9BND-D Secondary Reference Temperature Standards with 5-Pin DIN for Tweener Thermometers, 9 x 0.188in, 90° Bend

Model: 5615-9BND-D | UPC: 95969794176

Fluke 5615-9BND-D Secondary Reference Temperature Standards with 5-Pin DIN for Tweener Thermometers, 9 x 0.188in, 90° Bend-

Fluke 5615-9BND-D Secondary Reference Temperature Standards with 5-Pin DIN for Tweener Thermometers, 9 x 0.188in, 90° Bend

Model: 5615-9BND-D

This Inconel-sheathed secondary reference temperature standard features a durable design thanks to its fully supported sensing element, which is surrounded in a ceramic case with a moisture- and contaminant-resistant hermetic glass seal. The 90°-bent temperature standard is ideal for use in the factory, field or lab and features 5-pin DIN connections and 9 x 0.188in sizing.

This Inconel-sheathed secondary reference temperature standard features a durable design thanks to its fully supported sensing element, which is surrounded in a ceramic case with a moisture- and contaminant-resistant hermetic glass seal. The 90°-bent temperature standard is ideal for use in the factory, field or lab and features 5-pin DIN connections and 9 x 0.188in sizing.

Your Price $1350.00 USD
Availability 2 to 3 Weeks
Quantity

Fluke 5615-9BND-D Offers

It bridges the gap between a 100Ω industrial RTD and an SPRT.

Features

  • Wide-range accuracy
  • Excellent stability
  • Reference-grade platinum sensing element
  • NVLAP-accredited calibration included, lab code 200706-0

Fluke 5615-9BND-D Specifications

Temperature Range -328 to 572°F (-200 to 300°C)
Nominal Resistance At 0°C 100Ω ±0.10Ω
Temperature Coefficient 0.0039250Ω/Ω/°C
Accuracy (Includes Calibration And 100-Hour Drift (k=2)) ±0.024°C at -200°C; ±0.012°C at 0°C; ±0.035°C at 420°C
Drift (After 100 Hours At Max Temp, 95% Confidence (k=2)) ±0.007°C at 0.010°C
Sensor Length 1.1in (28mm)
Sensor Location 0.27in ±0.13in (6.9mm ±3.3mm) from tip
Lead-Wire Cable Type PTFE insulated with PTFE jacket, 22AWG
Lead-Wire Length 6ft (183cm)
Calibration NVLAP-accredited calibration included, lab code 200706-0

What's included with the Fluke 5615-9BND-D

  • Fluke 5615-9BND-D Secondary Reference Temperature Standards with 5-Pin DIN for Tweener Thermometers, 9 x 0.188in, 90° Bend
  • Customer Reviews for the Fluke 5615-9BND-D

    Ask a question about Fluke 5615-9BND-D Secondary Reference Temperature Standards with 5-Pin DIN for Tweener Thermometers, 9 x 0.188in, 90° Bend

    Fluke 5615-9BND-D Offers

    It bridges the gap between a 100Ω industrial RTD and an SPRT.

    Features

    • Wide-range accuracy
    • Excellent stability
    • Reference-grade platinum sensing element
    • NVLAP-accredited calibration included, lab code 200706-0

    Fluke 5615-9BND-D Specifications

    Temperature Range -328 to 572°F (-200 to 300°C)
    Nominal Resistance At 0°C 100Ω ±0.10Ω
    Temperature Coefficient 0.0039250Ω/Ω/°C
    Accuracy (Includes Calibration And 100-Hour Drift (k=2)) ±0.024°C at -200°C; ±0.012°C at 0°C; ±0.035°C at 420°C
    Drift (After 100 Hours At Max Temp, 95% Confidence (k=2)) ±0.007°C at 0.010°C
    Sensor Length 1.1in (28mm)
    Sensor Location 0.27in ±0.13in (6.9mm ±3.3mm) from tip
    Lead-Wire Cable Type PTFE insulated with PTFE jacket, 22AWG
    Lead-Wire Length 6ft (183cm)
    Calibration NVLAP-accredited calibration included, lab code 200706-0