Fluke 5616-12-J Secondary Reference Temperature Standards with Banana Plugs, 12 x 0.25in

Model: 5616-12-J | UPC: 095969416665

Fluke 5616-12-J Secondary Reference Temperature Standards with Banana Plugs, 12 x 0.25in-


Downloads: datasheet

Fluke 5616-12-J Secondary Reference Temperature Standards with Banana Plugs, 12 x 0.25in

Model: 5616-12-J

With a wide temperature range and high-purity platinum element, this secondary reference temperature standard is ideal for lab or field calibration. The temperature standard measures 12 x 0.25in and has banana plug connections.

With a wide temperature range and high-purity platinum element, this secondary reference temperature standard is ideal for lab or field calibration. The temperature standard measures 12 x 0.25in and has banana plug connections.

This product has been discontinued. Click here for the replacement model(s).


Fluke 5616-12-J Offers

It bridges the gap between a 100Ω industrial RTD and an SPRT.

Features

  • Wide-range accuracy
  • Excellent stability
  • Reference-grade platinum sensing element
  • NVLAP-accredited calibration included, lab code 200706-0

Fluke 5616-12-J Specifications

Temperature Range -328 to 572°F (-200 to 300°C)
Nominal Resistance At 0°C 100Ω ±0.10Ω
Temperature Coefficient 0.0039250Ω/Ω/°C
Accuracy (Includes Calibration And 100-Hour Drift (k=2)) ±0.024°C at -200°C; ±0.012°C at 0°C; ±0.035°C at 420°C
Drift (After 100 Hours At Max Temp, 95% Confidence (k=2)) ±0.007°C at 0.010°C
Sensor Length 1.1in (28mm)
Sensor Location 0.27in ±0.13in (6.9mm ±3.3mm) from tip
Lead-Wire Cable Type PTFE insulated with PTFE jacket, 22AWG
Lead-Wire Length 6ft (183cm)
Calibration NVLAP-accredited calibration included, lab code 200706-0
Click here for complete specifications on the Fluke 5616-12-J

What's included with the Fluke 5616-12-J

  • Fluke 5616-12-J Secondary Reference Temperature Standards with Banana Plugs, 12 x 0.25in
  • Customer Reviews for the Fluke 5616-12-J

    Ask a question about Fluke 5616-12-J Secondary Reference Temperature Standards with Banana Plugs, 12 x 0.25in

    Fluke 5616-12-J Offers

    It bridges the gap between a 100Ω industrial RTD and an SPRT.

    Features

    • Wide-range accuracy
    • Excellent stability
    • Reference-grade platinum sensing element
    • NVLAP-accredited calibration included, lab code 200706-0

    Fluke 5616-12-J Specifications

    Temperature Range -328 to 572°F (-200 to 300°C)
    Nominal Resistance At 0°C 100Ω ±0.10Ω
    Temperature Coefficient 0.0039250Ω/Ω/°C
    Accuracy (Includes Calibration And 100-Hour Drift (k=2)) ±0.024°C at -200°C; ±0.012°C at 0°C; ±0.035°C at 420°C
    Drift (After 100 Hours At Max Temp, 95% Confidence (k=2)) ±0.007°C at 0.010°C
    Sensor Length 1.1in (28mm)
    Sensor Location 0.27in ±0.13in (6.9mm ±3.3mm) from tip
    Lead-Wire Cable Type PTFE insulated with PTFE jacket, 22AWG
    Lead-Wire Length 6ft (183cm)
    Calibration NVLAP-accredited calibration included, lab code 200706-0
    Click here for complete specifications on the Fluke 5616-12-J

    What's included with the Fluke 5616-12-J

  • Fluke 5616-12-J Secondary Reference Temperature Standards with Banana Plugs, 12 x 0.25in
  • Ask a question about Fluke 5616-12-J Secondary Reference Temperature Standards with Banana Plugs, 12 x 0.25in

    Customer Reviews for the Fluke 5616-12-J

    More Fluke Products