Fluke i2000 FLEX Flexible AC Current Clamp

Model: I2000-FLEX | UPC: 095969345088

Fluke i2000 FLEX Flexible AC Current Clamp-


Downloads: datasheet manual

Fluke i2000 FLEX Flexible AC Current Clamp

Model: I2000-FLEX

Utilizing the Rogowski principle, the clamp can be used to measure currents up to 2000 A when used in conjunction with multimeters, recorders, or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.

Utilizing the Rogowski principle, the clamp can be used to measure currents up to 2000 A when used in conjunction with multimeters, recorders, or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.

Sale Price $400.49 USD
Regular Price $444.99 USD
Availability 2 to 3 Weeks
Quantity

Add In-House Traceable Calibration to your I2000-FLEX

Add In-House Traceable Calibration to your I2000-FLEX


Fluke I2000-FLEX Offers

Features

  • Three ranges: 20 A, 200 A & 2000 A, 100 mV/A, 10 mV/A & 1 mV/A output
  • Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
  • Maximum conductor diameter 7" (178 mm)
  • CAT III 600 V safety rating

Fluke I2000-FLEX Specifications

Current Ranges 20 A, 200 A, 2000 A ACRMS
Output Sensitivity (AC-Coupled) 100 mV, 10 mV, 1 mV per A
Load Impedance 100 kΩ minimum
Accuracy (at 25°C) ±1% of range (45 to 65 Hz)
Linearity (10 to 100% of range) ±0.2% of reading
Noise 8 mV ac rms (30 A), 2 mV ac rms (300 A, 3000 A)
Frequency Range 10 Hz to 20 kHz (-3 dB)
Phase Error < ±1° (45 to 65 Hz), : ±10° (at 20 kHz)
Position Sensitivity (with cable >25 mm from the coupling) ±2% of range
External Field (with cable >200 mm from the head) ±1% of range
Power Supply 2 x AA/MN 1500/LR6 Alkaline, 200 hours, low battery indicator
Temperature Coefficient ±0.08% of reading per °C
Working Voltage 600 V ac rms or dc
Head Cable Length (double insulated): 24" (610 mm)
Diameter: 0.56" (14.3 mm)
Head Bend Radius 1.5" (38.1 mm)
Cable Length (head to electronics) 6.56' (2 m)
Output Connection BNC with BNC to Banana adapter included
Operating Temperature Range 32 to 158°F (0 to 70°C) (head and electronics)
Storage Temperature Range -40 to 221°F (-40 to 105°C) (head)
-4 to 185°F (-20 to 85°C) (electronics)
Operating Humidity 15 to 85% (non-condensing)
Weight 6.34 oz (180 g) (head), 6.70 oz (190 g) (electronics)
Safety Standards EN 61010-1: 2001
EN 61010-2-032: 2002
EN 61010-031: 2002
600 Vrms, Category III, Pollution Degree 2
EMC Standards EN 61326: 1998 +A1, A2, & A3
Click here for complete specifications on the Fluke I2000-FLEX

What's included with the Fluke I2000-FLEX

  • Fluke i2000 FLEX Flexible AC Current Clamp
  • Customer Reviews for the Fluke I2000-FLEX

    Ask a question about Fluke i2000 FLEX Flexible AC Current Clamp

    Fluke I2000-FLEX Offers

    Features

    • Three ranges: 20 A, 200 A & 2000 A, 100 mV/A, 10 mV/A & 1 mV/A output
    • Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
    • Maximum conductor diameter 7" (178 mm)
    • CAT III 600 V safety rating

    Fluke I2000-FLEX Specifications

    Current Ranges 20 A, 200 A, 2000 A ACRMS
    Output Sensitivity (AC-Coupled) 100 mV, 10 mV, 1 mV per A
    Load Impedance 100 kΩ minimum
    Accuracy (at 25°C) ±1% of range (45 to 65 Hz)
    Linearity (10 to 100% of range) ±0.2% of reading
    Noise 8 mV ac rms (30 A), 2 mV ac rms (300 A, 3000 A)
    Frequency Range 10 Hz to 20 kHz (-3 dB)
    Phase Error < ±1° (45 to 65 Hz), : ±10° (at 20 kHz)
    Position Sensitivity (with cable >25 mm from the coupling) ±2% of range
    External Field (with cable >200 mm from the head) ±1% of range
    Power Supply 2 x AA/MN 1500/LR6 Alkaline, 200 hours, low battery indicator
    Temperature Coefficient ±0.08% of reading per °C
    Working Voltage 600 V ac rms or dc
    Head Cable Length (double insulated): 24" (610 mm)
    Diameter: 0.56" (14.3 mm)
    Head Bend Radius 1.5" (38.1 mm)
    Cable Length (head to electronics) 6.56' (2 m)
    Output Connection BNC with BNC to Banana adapter included
    Operating Temperature Range 32 to 158°F (0 to 70°C) (head and electronics)
    Storage Temperature Range -40 to 221°F (-40 to 105°C) (head)
    -4 to 185°F (-20 to 85°C) (electronics)
    Operating Humidity 15 to 85% (non-condensing)
    Weight 6.34 oz (180 g) (head), 6.70 oz (190 g) (electronics)
    Safety Standards EN 61010-1: 2001
    EN 61010-2-032: 2002
    EN 61010-031: 2002
    600 Vrms, Category III, Pollution Degree 2
    EMC Standards EN 61326: 1998 +A1, A2, & A3