1-888-610-7664

sales@GlobalTestSupply.com

Chat Live

Customer Reviews

Fluke MDA-510 Motor Drive Analyzer, 4 Channel, 500 MHz

Model: MDA-510 | UPC: 095969870962

Fluke MDA-510 Motor Drive Analyzer, 4 Channel, 500 MHz-


Downloads: datasheet

Fluke MDA-510 Motor Drive Analyzer, 4 Channel, 500 MHz

Model: MDA-510

Featuring a portable motor-drive analysis tool that can help to simplify complex motor-drive troubleshooting with guided test setups and automated drive measurements that provide reliable, repeatable test results. It offers basic to advanced measurements, along with a built-in report generator to quickly and easily generate as-found and as-left reports.

Featuring a portable motor-drive analysis tool that can help to simplify complex motor-drive troubleshooting with guided test setups and automated drive measurements that provide reliable, repeatable test results. It offers basic to advanced measurements, along with a built-in report generator to quickly and easily generate as-found and as-left reports.

Your Price $6699.99 USD
Availability 2 to 3 Weeks
Quantity

Fluke MDA-510 Offers

This motor-drive analyzer saves time and eliminates the hassle of setting up complex measurements, while simplifying the troubleshooting process. Simply select a test and the step-by-step guided measurements show you where to make voltage and current connections, while the preset measurement profiles ensure you will capture all the data you need for each critical motor-drive section—from the input to the output, the DC bus, and the motor itself. From basic to advanced measurements, this tool has you covered, and with a built-in report generator you can quickly and easily generate as-found, and as-left reports with confidence. It is the ideal portable motor-drive analysis test tool, and can help safely locate and troubleshoot typical problems on inverter type motor-drive systems.

Features

  • Key measurements: inverter output voltage, DC bus voltage and ripple voltage, and unbalance
  • Three powerful test tools in one: motor-drive analyzer, waveform analyzer and recording data logger all in one
  • Measure key motor-drive parameters including voltage, current, DC Bus voltage level and AC ripple, voltage and current unbalance, and voltage modulation
  • Conduct guided measurements for motor-drive input, DC bus, and drive output with graphical step-by-step voltage and current connection diagrams
  • Use simplified measurement setup with preset measurement profiles to automatically trigger data collection based on the chosen test procedure
  • Create reports quickly and easily that are perfect for documenting troubleshooting and collaborative work with others
  • Measure additional electrical parameters with full 500 MHz oscilloscope, meter and recording capability for complete range of electrical and electronic measurement on industrial systems
  • Highest safety rating - 600 V CAT IV/1000 V CAT III rated for use at the service entrance and downstream

Drive Input

Measure input voltage and current to quickly see whether values are within acceptable limits by comparing the drive's nominal rated voltage to the actual supplied voltage. Then, check the input current to determine if the current is within the maximum rating and the conductors are suitably sized.

Voltage and Current Unbalance

Check the voltage unbalance at the input terminals so you can ensure the phase unbalance is not too high (>6 to 8%), and that the phase rotation is correct. You can also check the current unbalance, as excessive unbalance may indicate a drive rectifier problem.

DC Bus

In a motor-drive the conversion of AC to DC inside the drive is critical, having the correct voltage and adequate smoothing with low ripple is required for the best drive performance. High ripple voltage may be an indicator of failed capacitors or incorrect sizing of the connected motor. The record function can be used to check DC bus performance dynamically in the operating mode while a load is applied.

Drive Output

Check the output of the drive focusing both on voltage to frequency ratio (V/F), and voltage modulation. When high V/F ratio measurements are experienced, the motor may overheat. With low V/F ratios, the connected motor may not be able to provide the required torque at the load to sufficiently run the intended process.

Voltage Modulation

Measurements of the Pulse Width Modulated signal are used to check for high voltage peaks which can damage motor winding insulation. The rise time or steepness of impulses is indicated by the dV/dt reading (rate of voltage change over time), this should be compared to the motor's specified insulation. The measurements can also be used to measure switching frequency to identify whether there is a potential issue with electronic switching, or with grounding, where the signal floats up and down.

Motor Input

Ensuring that voltage is being supplied at the motor input terminals is key, and the selection of cabling from drive to the motor is critical. Incorrect cabling selection can result in both drive and motor damage due to excessive reflected voltage peaks. Checking that the current present at the terminals is within the motor rating is important as over current condition could cause the motor to run hot, decreasing the life of the stator insulation which can result in the early failure of the motor.

Step-by-Step Guided Measurements Ensure You Have the Data You Need, When You Need It

Designed to help you quickly and easily test and troubleshoot typical problems on three-phase and single-phase inverter type motor-drive systems. The on-screen information, and step-by-step setup guidance make it easy to con- figure the analyzer and get the drive measurements you need to make better maintenance decisions, fast. From power input to the installed motor, it provides the measurement capability for the fastest motor-drive troubleshooting.

Reporting and Analysis

Simplifies the process of gathering data and writing test reports with a built-in report generator. At each test point or measurement there is the option to create, update or modify a report. Simply press ‘SAVE TO REPORT' and select the appropriate screens to save into a text based report file. By performing the step-by-step guided measurements a comprehensive report can be created directly from the instrument to document the entire troubleshooting process. Input the report name. The single report encompasses all recorded measurements and can easily be shared with other users and used for motor- drive benchmarking, and for comparing data now and in the future.


Applications

  • Industrial automation
  • HVAC/R
  • Motor repair
  • Discrete or process based industrial manufacturing
  • Waste water treatment
  • Oil and gas maintenance

Fluke MDA-510 Specifications

DC Voltage (V DC)
Maximum Voltage with 10:1 or 100:1 Probe 1000 V
Maximum Resolution with 10:1 or 100:1 Probe 1 mV
Full Scale Reading 999 counts
Accuracy at 4 s to 10 us/div ±(3% + 6 counts)
AC Voltage (V AC)
Maximum Voltage with 10:1 or 100:1 Probe 1000 V
Maximum Resolution with 10:1 or 100:1 Probe 1 mV
Full Scale Reading 999 counts
50 Hz ±(3% + 10 counts) - 0.6%
60 Hz ±(3% + 10 counts) - 0.4%
60 Hz to 20 kHz ±(4% + 15 counts)
20 kHz to 1 MHz ±(6% + 20 counts)
1 MHz to 25 MHz ±(10% + 20 counts)
True-RMS Voltage (V AC+DC)
Maximum Voltage with 10:1 or 100:1 Probe 1000 V
Maximum Resolution with 10:1 or 100:1 Probe 1 mV
Full Scale Reading 1100 counts
DC to 60 Hz ±(3% + 10 counts)
60 Hz to 20 kHz ±(4% + 15 counts)
20 kHz to 1 MHz ±(6% + 20 counts)
1 MHz to 25 MHz ±(10% + 20 counts)
Peak Voltage (V Peak)
Modes Max peak, min peak, or pk-to-pk
Maximum Voltage with 10:1 or 100:1 Probe 1000 V
Maximum Resolution with 10:1 or 100:1 Probe 10 mV
Max/Min Peak ±0.2 division
Pk-to-Pk ±0.4 division
Full Scale Reading 800 counts
Frequency (Hz)
Range 1.000 Hz to 500 MHz
Full Scale Reading 999 counts
Accuracy ±(0.5% + 2 counts)
Click here for complete specifications on the Fluke MDA-510

What's included with the Fluke MDA-510

  • Motor Drive Analyzer
  • 3 x VPS 100:1 High Voltage Probes with Alligator Clips
  • VPS410-II-R 10:1 500 MHz Voltage Probe
  • i400s AC Current Clamp
  • BC190 Charger/Power Adapter
  • 2 GB USB Drive
  • FlukeView™ 2 Software
  • C1740 Carrying Case
  • BP 291 Li-Ion Battery Pack
  • Manual

Webinar: Introduction to Portable Precision Power Analyzers with Fluke


This wideband precision analyzer is accurate enough for the lab, yet it's built for the field. Offering you more freedom than ever before to make high accuracy power measurements wherever you need to. Whether in the lab, or in the field. Designed for portability and eliminates the need to carry large, fragile, expensive analyzers into the field, allowing you to make measurements directly at the load in nearly any environment. By measuring directly at the load, you can discover how the equipment operates under real-world conditions, with real-world variables, not just at a test bench or in the lab.
During our 1-hour webinar, we've covered:
- The new Fluke Norma 6000 Power Analyzer for accurate measurements at frequencies from DC to 500kHz.
- It is not a Power Quality Analyzer.
- It is a Power Analyzer for accurate measurements at frequencies from DC to 500kHz.
- It is designed to be used in the field, its rugged, battery-operated, lightweight, and suited to use outside of a laboratory environment.
- You’ll learn why it can help you, where and how it is used.

Click on a category to view a selection of compatible accessories with the Fluke MDA-510 Motor Drive Analyzer, 4 Channel, 500 MHz.

Fluke SVS-500 Shaft Voltage Set and Magnetic Base for the MDA-500 Series SVS-500
For use with MDA-500 Motor Drive Analyzer models.




Fluke SB-500 Shaft Brushes Set for the SVS-500 and MDA-500 Series SB-500
For use with MDA-500 Motor Drive Analyzer models.




Customer Reviews for the Fluke MDA-510

Ask a question about Fluke MDA-510 Motor Drive Analyzer, 4 Channel, 500 MHz

Fluke MDA-510 Offers

This motor-drive analyzer saves time and eliminates the hassle of setting up complex measurements, while simplifying the troubleshooting process. Simply select a test and the step-by-step guided measurements show you where to make voltage and current connections, while the preset measurement profiles ensure you will capture all the data you need for each critical motor-drive section—from the input to the output, the DC bus, and the motor itself. From basic to advanced measurements, this tool has you covered, and with a built-in report generator you can quickly and easily generate as-found, and as-left reports with confidence. It is the ideal portable motor-drive analysis test tool, and can help safely locate and troubleshoot typical problems on inverter type motor-drive systems.

Features

  • Key measurements: inverter output voltage, DC bus voltage and ripple voltage, and unbalance
  • Three powerful test tools in one: motor-drive analyzer, waveform analyzer and recording data logger all in one
  • Measure key motor-drive parameters including voltage, current, DC Bus voltage level and AC ripple, voltage and current unbalance, and voltage modulation
  • Conduct guided measurements for motor-drive input, DC bus, and drive output with graphical step-by-step voltage and current connection diagrams
  • Use simplified measurement setup with preset measurement profiles to automatically trigger data collection based on the chosen test procedure
  • Create reports quickly and easily that are perfect for documenting troubleshooting and collaborative work with others
  • Measure additional electrical parameters with full 500 MHz oscilloscope, meter and recording capability for complete range of electrical and electronic measurement on industrial systems
  • Highest safety rating - 600 V CAT IV/1000 V CAT III rated for use at the service entrance and downstream

Drive Input

Measure input voltage and current to quickly see whether values are within acceptable limits by comparing the drive's nominal rated voltage to the actual supplied voltage. Then, check the input current to determine if the current is within the maximum rating and the conductors are suitably sized.

Voltage and Current Unbalance

Check the voltage unbalance at the input terminals so you can ensure the phase unbalance is not too high (>6 to 8%), and that the phase rotation is correct. You can also check the current unbalance, as excessive unbalance may indicate a drive rectifier problem.

DC Bus

In a motor-drive the conversion of AC to DC inside the drive is critical, having the correct voltage and adequate smoothing with low ripple is required for the best drive performance. High ripple voltage may be an indicator of failed capacitors or incorrect sizing of the connected motor. The record function can be used to check DC bus performance dynamically in the operating mode while a load is applied.

Drive Output

Check the output of the drive focusing both on voltage to frequency ratio (V/F), and voltage modulation. When high V/F ratio measurements are experienced, the motor may overheat. With low V/F ratios, the connected motor may not be able to provide the required torque at the load to sufficiently run the intended process.

Voltage Modulation

Measurements of the Pulse Width Modulated signal are used to check for high voltage peaks which can damage motor winding insulation. The rise time or steepness of impulses is indicated by the dV/dt reading (rate of voltage change over time), this should be compared to the motor's specified insulation. The measurements can also be used to measure switching frequency to identify whether there is a potential issue with electronic switching, or with grounding, where the signal floats up and down.

Motor Input

Ensuring that voltage is being supplied at the motor input terminals is key, and the selection of cabling from drive to the motor is critical. Incorrect cabling selection can result in both drive and motor damage due to excessive reflected voltage peaks. Checking that the current present at the terminals is within the motor rating is important as over current condition could cause the motor to run hot, decreasing the life of the stator insulation which can result in the early failure of the motor.

Step-by-Step Guided Measurements Ensure You Have the Data You Need, When You Need It

Designed to help you quickly and easily test and troubleshoot typical problems on three-phase and single-phase inverter type motor-drive systems. The on-screen information, and step-by-step setup guidance make it easy to con- figure the analyzer and get the drive measurements you need to make better maintenance decisions, fast. From power input to the installed motor, it provides the measurement capability for the fastest motor-drive troubleshooting.

Reporting and Analysis

Simplifies the process of gathering data and writing test reports with a built-in report generator. At each test point or measurement there is the option to create, update or modify a report. Simply press ‘SAVE TO REPORT' and select the appropriate screens to save into a text based report file. By performing the step-by-step guided measurements a comprehensive report can be created directly from the instrument to document the entire troubleshooting process. Input the report name. The single report encompasses all recorded measurements and can easily be shared with other users and used for motor- drive benchmarking, and for comparing data now and in the future.


Applications

  • Industrial automation
  • HVAC/R
  • Motor repair
  • Discrete or process based industrial manufacturing
  • Waste water treatment
  • Oil and gas maintenance

Fluke MDA-510 Specifications

DC Voltage (V DC)
Maximum Voltage with 10:1 or 100:1 Probe 1000 V
Maximum Resolution with 10:1 or 100:1 Probe 1 mV
Full Scale Reading 999 counts
Accuracy at 4 s to 10 us/div ±(3% + 6 counts)
AC Voltage (V AC)
Maximum Voltage with 10:1 or 100:1 Probe 1000 V
Maximum Resolution with 10:1 or 100:1 Probe 1 mV
Full Scale Reading 999 counts
50 Hz ±(3% + 10 counts) - 0.6%
60 Hz ±(3% + 10 counts) - 0.4%
60 Hz to 20 kHz ±(4% + 15 counts)
20 kHz to 1 MHz ±(6% + 20 counts)
1 MHz to 25 MHz ±(10% + 20 counts)
True-RMS Voltage (V AC+DC)
Maximum Voltage with 10:1 or 100:1 Probe 1000 V
Maximum Resolution with 10:1 or 100:1 Probe 1 mV
Full Scale Reading 1100 counts
DC to 60 Hz ±(3% + 10 counts)
60 Hz to 20 kHz ±(4% + 15 counts)
20 kHz to 1 MHz ±(6% + 20 counts)
1 MHz to 25 MHz ±(10% + 20 counts)
Peak Voltage (V Peak)
Modes Max peak, min peak, or pk-to-pk
Maximum Voltage with 10:1 or 100:1 Probe 1000 V
Maximum Resolution with 10:1 or 100:1 Probe 10 mV
Max/Min Peak ±0.2 division
Pk-to-Pk ±0.4 division
Full Scale Reading 800 counts
Frequency (Hz)
Range 1.000 Hz to 500 MHz
Full Scale Reading 999 counts
Accuracy ±(0.5% + 2 counts)
Click here for complete specifications on the Fluke MDA-510

What's included with the Fluke MDA-510

  • Motor Drive Analyzer
  • 3 x VPS 100:1 High Voltage Probes with Alligator Clips
  • VPS410-II-R 10:1 500 MHz Voltage Probe
  • i400s AC Current Clamp
  • BC190 Charger/Power Adapter
  • 2 GB USB Drive
  • FlukeView™ 2 Software
  • C1740 Carrying Case
  • BP 291 Li-Ion Battery Pack
  • Manual

Webinar: Introduction to Portable Precision Power Analyzers with Fluke


This wideband precision analyzer is accurate enough for the lab, yet it's built for the field. Offering you more freedom than ever before to make high accuracy power measurements wherever you need to. Whether in the lab, or in the field. Designed for portability and eliminates the need to carry large, fragile, expensive analyzers into the field, allowing you to make measurements directly at the load in nearly any environment. By measuring directly at the load, you can discover how the equipment operates under real-world conditions, with real-world variables, not just at a test bench or in the lab.
During our 1-hour webinar, we've covered:
- The new Fluke Norma 6000 Power Analyzer for accurate measurements at frequencies from DC to 500kHz.
- It is not a Power Quality Analyzer.
- It is a Power Analyzer for accurate measurements at frequencies from DC to 500kHz.
- It is designed to be used in the field, its rugged, battery-operated, lightweight, and suited to use outside of a laboratory environment.
- You’ll learn why it can help you, where and how it is used.

Click on a category to view a selection of compatible accessories with the Fluke MDA-510 Motor Drive Analyzer, 4 Channel, 500 MHz.

Fluke SVS-500 Shaft Voltage Set and Magnetic Base for the MDA-500 Series SVS-500
For use with MDA-500 Motor Drive Analyzer models.




Fluke SB-500 Shaft Brushes Set for the SVS-500 and MDA-500 Series SB-500
For use with MDA-500 Motor Drive Analyzer models.




Ask a question about Fluke MDA-510 Motor Drive Analyzer, 4 Channel, 500 MHz

Customer Reviews for the Fluke MDA-510

More Fluke Products