1-888-610-7664

sales@GlobalTestSupply.com

Chat Live

Customer Reviews

Fluke 725US-NIST Multifunction Process Calibrator, includes Traceable Certificate

Model: 725US-NIST

Fluke 725US-NIST Multifunction Process Calibrator, -


Downloads: datasheet manual

Fluke 725US-NIST Multifunction Process Calibrator, includes Traceable Certificate

Model: 725US-NIST

Easily source and measure a wide variety of process parameters and test many process devices. This unit is capable of measuring and sourcing mA, volts, temperature (RTDs and thermocouples), frequency, ohms, and pressure, using optional pressure modules. This product includes a Traceable Certificate with full Data and Uncertainties.

Easily source and measure a wide variety of process parameters and test many process devices. This unit is capable of measuring and sourcing mA, volts, temperature (RTDs and thermocouples), frequency, ohms, and pressure, using optional pressure modules.

Your Price $3289.99 USD
Availability 3 Days
Quantity

Fluke 725US-NIST Offers

This product includes a Traceable Certificate with full Data and Uncertainties.

Features

  • Powerful, easy-to-use field calibrator
  • Measures volts, mA, pressure, RTDs, thermocouples, frequency, and ohms to test sensors and transmitters
  • Sources/simulates volts dc, mA, thermocouples , RTDs, frequency, ohms, and pressure to calibrate transmitters
  • Measures/sources pressure using any of 50 750P Pressure Modules (sold separately)
  • Easy to read measure/source screen displays input and output simultaneously
  • Powers transmitters during test using loop supply with simultaneous mA measurement
  • Handles fast pulsed RTD transmitters and PLCs, with pulses as short as 10 ms
  • Provides a backlit display to provide better visibility in poor light
  • Features small, streamlined shape, and rugged, reliable design that stands up to field use
  • Sources mA with simultaneous pressure measurement to conduct valve and I/P tests
  • Supports flow meter testing with frequency and CPM functions
  • Performs fast linearity tests with auto-step and auto-ramp features

Fluke 725US-NIST Specifications

Measurement Accuracy
Voltage DC 30.000 V: 0.02% + 2 counts (upper display)
30.000 V: 0.02% + 2 counts (lower display)
100.00 mV: 0.02% + 2 counts
-10.00 to 75.00 mV: 0.025% + 1 count (via TC connector)
Current DC 24.000 mA: 0.02% + 2 counts
Resistance 0.0 to 400.0 Ω: 0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire)
401 to 1500 Ω: 0.5 Ω (4-wire), 1 Ω (2- and 3-wire)
1500 to 3200 Ω: 1 Ω (4-wire), 1.5 Ω (2- and 3-wire)
Frequency 2.0 to 1000.0 CPM: 0.05% + 1 count
1.0 to 1100.0 Hz: 0.05% + 1 count
1.00 to 10.00 kHz: 0.05% + 1 count
Sensitivity: 1 V peak-to-peak-minimum
Pressure Accuracy from 0.025% of range using any of 29 pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure.
Source Accuracy
Voltage DC 100.00 mV: 0.02% + 2 counts
10.000 V: 0.02% + 2 counts
-10.00 to 75.00 mV: 0.025% + 1 count (via TC connector)
Current DC 24.000 mA (source): 0.02% + 2 counts
24.000 mA (simulate): 0.02% + 2 counts
Resistance 15.0 to 400.0 Ω: 0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA)
401 to 1500 Ω: 0.5 Ω (excitation current 0.05 to 0.8 mA)
1500 to 3200 Ω: 1 Ω (excitation current 0.05 to 0.4 mA)
Frequency 2.0 to 1000.0 CPM: 0.05%
1.0 to 1100.0 Hz: 0.05%
1.00 to 10.00 kHz: 0.25%
Waveform: 5 V p-p squarewave, -0.1 V offset
RTDs and Thermocouples
Measure Accuracy NI-120: 32.36°F (0.2°C)
PT-100 (385): 32.6°F (0.33°C)
PT-100 (393): 32.54°F (0.3°C)
PT-100 (JIS): 32.54°F (0.3°C)
PT-200 (385): 32.36°F (0.2°C)
PT-500 (385): 32.54°F (0.3°C)
PT-1000 (385): 32.36°F (0.2°C)
Resolution: 0.1°C
J: 33.26°F (0.7°C)
K: 33.44°F (0.8°C)
T: 33.44°F (0.8°C)
E: 33.26°F (0.7°C)
R: 35.24°F (1.8°C)
S: 34.7°F (1.5°C)
B: 34.52°F (1.4°C)
L: 33.26°F (0.7°C)
U: 33.35°F (0.75°C)
N: 33.62°F (0.9°C)
Resolution: J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F
XK: 33.08°F (0.6°C)
BP: 34.16°F (1.2°C)
Source Accuracy NI-120: 32.36°F (0.2°C)
PT-100 (385): 32.6°F (0.33°C)
PT-100 (393): 32.54°F (0.3°C)
PT-100 (JIS): 32.54°F (0.3°C)
PT-200 (385): 32.36°F (0.2°C)
PT-500 (385): 32.54°F (0.3°C)
PT-1000 (385): 32.36°F (0.2°C)
Resolution: 0.1°C
Accuracy stated for 4-wire measurement
J: 33.26°F (0.7°C)
K: 33.44°F (0.8°C)
T: 33.44°F (0.8°C)
E: 33.26°F (0.7°C)
R: 34.52°F (1.4°C)
S: 34.7°F (1.5°C)
B: 34.52°F (1.4°C)
L: 33.26°F (0.7°C)
U: 33.35°F (0.75°C)
N: 33.62°F (0.9°C)
Resolution: J, K, T, E, L, N, U: 0.1°C, B, R, S: 1°C
XK: 33.08°F (0.6°C)
BP: 34.16°F (1.2°C)
Functions Specifications
Ramp Functions Source functions: Voltage, current, resistance, frequency, temperature
Ramps: Slow ramp, Fast ramp, 25% step-ramp
Loop Power Function Voltage: 24 V
Accuracy: 10%
Maximum current: 22 mA, short circuit protected
Step Functions Source functions: Voltage, current, resistance, frequency, temperature
Steps: 25% of range, 100% of range
Environmental Specifications
Operating Temperature 14 to 131°F (-10 to 55°C)
Storage Temperature -4 to 159.8°F (-20 to 71°C)
Operating Altitude 9842.52' (3000 m)
Mechanical and General Specifications
Batteries 4 x AA alkaline batteries
Battery Replacement Separate battery compartment, accessable without breaking calibration seal
Side Port Connections Pressure module connector, also used for remote real-time programming
Dimensions 5.1 x 9.3 x 2.4" (130 x 236 x 61 mm)
Weight 1.43 lbs (0.65 kg)
Safety Specifications
Agency Approvals EN 61010-1:1993, ANSI/ISA S82.01-1994; CAN/CSA C22.2 No 1010.1:1992
Click here for complete specifications on the Fluke 725US-NIST

What's included with the Fluke 725US-NIST

  • Process Calibrator
  • Traceable Certificate with full Data and Uncertainties
  • Test Leads
  • Test Clips
  • Stackable Test Leads
  • Users Manuals
  • Statement of Quality Assurance Practices
  • CE and CSA Markings

Customer Reviews for the Fluke 725US-NIST

Ask a question about Fluke 725US-NIST Multifunction Process Calibrator,

Fluke 725US-NIST Offers

This product includes a Traceable Certificate with full Data and Uncertainties.

Features

  • Powerful, easy-to-use field calibrator
  • Measures volts, mA, pressure, RTDs, thermocouples, frequency, and ohms to test sensors and transmitters
  • Sources/simulates volts dc, mA, thermocouples , RTDs, frequency, ohms, and pressure to calibrate transmitters
  • Measures/sources pressure using any of 50 750P Pressure Modules (sold separately)
  • Easy to read measure/source screen displays input and output simultaneously
  • Powers transmitters during test using loop supply with simultaneous mA measurement
  • Handles fast pulsed RTD transmitters and PLCs, with pulses as short as 10 ms
  • Provides a backlit display to provide better visibility in poor light
  • Features small, streamlined shape, and rugged, reliable design that stands up to field use
  • Sources mA with simultaneous pressure measurement to conduct valve and I/P tests
  • Supports flow meter testing with frequency and CPM functions
  • Performs fast linearity tests with auto-step and auto-ramp features

Fluke 725US-NIST Specifications

Measurement Accuracy
Voltage DC 30.000 V: 0.02% + 2 counts (upper display)
30.000 V: 0.02% + 2 counts (lower display)
100.00 mV: 0.02% + 2 counts
-10.00 to 75.00 mV: 0.025% + 1 count (via TC connector)
Current DC 24.000 mA: 0.02% + 2 counts
Resistance 0.0 to 400.0 Ω: 0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire)
401 to 1500 Ω: 0.5 Ω (4-wire), 1 Ω (2- and 3-wire)
1500 to 3200 Ω: 1 Ω (4-wire), 1.5 Ω (2- and 3-wire)
Frequency 2.0 to 1000.0 CPM: 0.05% + 1 count
1.0 to 1100.0 Hz: 0.05% + 1 count
1.00 to 10.00 kHz: 0.05% + 1 count
Sensitivity: 1 V peak-to-peak-minimum
Pressure Accuracy from 0.025% of range using any of 29 pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure.
Source Accuracy
Voltage DC 100.00 mV: 0.02% + 2 counts
10.000 V: 0.02% + 2 counts
-10.00 to 75.00 mV: 0.025% + 1 count (via TC connector)
Current DC 24.000 mA (source): 0.02% + 2 counts
24.000 mA (simulate): 0.02% + 2 counts
Resistance 15.0 to 400.0 Ω: 0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA)
401 to 1500 Ω: 0.5 Ω (excitation current 0.05 to 0.8 mA)
1500 to 3200 Ω: 1 Ω (excitation current 0.05 to 0.4 mA)
Frequency 2.0 to 1000.0 CPM: 0.05%
1.0 to 1100.0 Hz: 0.05%
1.00 to 10.00 kHz: 0.25%
Waveform: 5 V p-p squarewave, -0.1 V offset
RTDs and Thermocouples
Measure Accuracy NI-120: 32.36°F (0.2°C)
PT-100 (385): 32.6°F (0.33°C)
PT-100 (393): 32.54°F (0.3°C)
PT-100 (JIS): 32.54°F (0.3°C)
PT-200 (385): 32.36°F (0.2°C)
PT-500 (385): 32.54°F (0.3°C)
PT-1000 (385): 32.36°F (0.2°C)
Resolution: 0.1°C
J: 33.26°F (0.7°C)
K: 33.44°F (0.8°C)
T: 33.44°F (0.8°C)
E: 33.26°F (0.7°C)
R: 35.24°F (1.8°C)
S: 34.7°F (1.5°C)
B: 34.52°F (1.4°C)
L: 33.26°F (0.7°C)
U: 33.35°F (0.75°C)
N: 33.62°F (0.9°C)
Resolution: J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F
XK: 33.08°F (0.6°C)
BP: 34.16°F (1.2°C)
Source Accuracy NI-120: 32.36°F (0.2°C)
PT-100 (385): 32.6°F (0.33°C)
PT-100 (393): 32.54°F (0.3°C)
PT-100 (JIS): 32.54°F (0.3°C)
PT-200 (385): 32.36°F (0.2°C)
PT-500 (385): 32.54°F (0.3°C)
PT-1000 (385): 32.36°F (0.2°C)
Resolution: 0.1°C
Accuracy stated for 4-wire measurement
J: 33.26°F (0.7°C)
K: 33.44°F (0.8°C)
T: 33.44°F (0.8°C)
E: 33.26°F (0.7°C)
R: 34.52°F (1.4°C)
S: 34.7°F (1.5°C)
B: 34.52°F (1.4°C)
L: 33.26°F (0.7°C)
U: 33.35°F (0.75°C)
N: 33.62°F (0.9°C)
Resolution: J, K, T, E, L, N, U: 0.1°C, B, R, S: 1°C
XK: 33.08°F (0.6°C)
BP: 34.16°F (1.2°C)
Functions Specifications
Ramp Functions Source functions: Voltage, current, resistance, frequency, temperature
Ramps: Slow ramp, Fast ramp, 25% step-ramp
Loop Power Function Voltage: 24 V
Accuracy: 10%
Maximum current: 22 mA, short circuit protected
Step Functions Source functions: Voltage, current, resistance, frequency, temperature
Steps: 25% of range, 100% of range
Environmental Specifications
Operating Temperature 14 to 131°F (-10 to 55°C)
Storage Temperature -4 to 159.8°F (-20 to 71°C)
Operating Altitude 9842.52' (3000 m)
Mechanical and General Specifications
Batteries 4 x AA alkaline batteries
Battery Replacement Separate battery compartment, accessable without breaking calibration seal
Side Port Connections Pressure module connector, also used for remote real-time programming
Dimensions 5.1 x 9.3 x 2.4" (130 x 236 x 61 mm)
Weight 1.43 lbs (0.65 kg)
Safety Specifications
Agency Approvals EN 61010-1:1993, ANSI/ISA S82.01-1994; CAN/CSA C22.2 No 1010.1:1992
Click here for complete specifications on the Fluke 725US-NIST

What's included with the Fluke 725US-NIST

  • Process Calibrator
  • Traceable Certificate with full Data and Uncertainties
  • Test Leads
  • Test Clips
  • Stackable Test Leads
  • Users Manuals
  • Statement of Quality Assurance Practices
  • CE and CSA Markings

Ask a question about Fluke 725US-NIST Multifunction Process Calibrator,