Perfect for field technicians who value safety, ease of use, and portability, this EV charging station analyzer provides predetermined test plans and pass/fail indicators, allowing thorough and efficient testing without needing multiple tools. In addition, this kit comes with an American-compatible type 1 plug.
Perfect for field technicians who value safety, ease of use, and portability, this EV charging station analyzer provides predetermined test plans and pass/fail indicators, allowing thorough and efficient testing without needing multiple tools. In addition, this kit comes with an American-compatible type 1 plug.
Test the safety and functionality of AC electrical vehicle charging stations with the all-in-one tool that is safe, portable, and efficient.
The FEV150 is a complete solution for safety and performance testing of AC EV charging stations with Type 1 (J1772) or Tesla-type connectors. Deliver uptime reliability with Fluke's next generation of EV Charging test solutions, designed for technicians to perform and document multiple tests safely, quickly, and efficiently without carrying multiple tools.
The FEV150 EV Charging Station Analyzer is compliant with J1772 standards.
Features
Applications
PE Pre-Test | |
Touch Voltage (safe range) | Display range: ≤50 V AC/DC Measurement range: ≤50 V AC/DC Operational error: -50% |
Touch Voltage (dangerous range) | Display range: >50 V AC/DC Measurement range: >50 V AC/DC Operational error: -0% |
GFCI Trip | |
Quick Trip | Display range: 30 mA, trip time limit: 0.56 seconds Measurement range: 30 mA, trip time limit: 0.56 seconds Operational error: Test current: 0 to 10% Nominal values: 100 to 253 V AC, 45 to 66 Hz |
Troubleshooting 6 mA GFCI | Display range: 3.5 mA, no trip Measurement range: 3.5 mA, no trip Operational error: Test current: -10 to 0% Nominal values: 100 to 253 V AC, 45 to 66 Hz Display range: 10 mA, trip time limit: 2.69 seconds Measurement range: 10 mA, trip time limit: 2.69 seconds Operational error: Test current: 0 to 10% Nominal values: 100 to 253 V AC, 45 to 66 Hz |
Troubleshooting 20 mA GFCI | Display range: 6 mA, no trip Measurement range: 6 mA, no trip Operational error: Test current: -10% to 0% Nominal values: 100 to 253 V AC, 45 to 66 Hz Display range: 30 mA, trip time limit: 0.56 seconds Measurement range: 30 mA, trip time limit: 0.56 seconds Operational error: Test current: 0 to 10% Nominal values: 100 to 253 V AC, 45 to 66 Hz |
Nominal Voltage | |
L1-L2/N | Display range: 0 to 280 V AC Measurement range: 0 to 253 V AC Operational error: ±(3% + 3 digits) Nominal values: 40 to 70 Hz, crest factor 2 |
Frequency | Display range: 40 to 70 Hz Measurement range: 40 to 70 Hz Operational error: ±0.20 Hz |
CP Signal Analysis | |
Voltage | Display range: -15 to 15 V Measurement range: -15 to -2 V, 2 to 15 V Operational error: ±0.5% Nominal values: RIN: 1 MΩ 0.9 to 1.1 kHz UCP+ >2 V, UCP- <-2 V |
PWM Duty Cycle | Display range: 2 to 98% Measurement range: 3 to 97% Operational error: ±5 digits Nominal values: RIN: 1 MΩ 0.9 to 1.1 kHz UCP+ >2 V, UCP- <-2 V |
Current Indication | Display range: 0 to 80 A Operational error: Based on duty cycle Nominal values: RIN: 1 MΩ 0.9 to 1.1 kHz UCP+ >2 V, UCP- <-2 V |
Frequency | Display range: 0.9 to 1.1 kHz (A, B, C, D) Measurement range: 0.9 to 1.1 kHz Operational error: 0.1% (based on voltage) Nominal values: RIN: 1 MΩ 0.9 to 1.1 kHz UCP+ >2 V, UCP- <-2 V |
CP State Indication | Display range: x1, x2 Operational error: Based on frequency Nominal values: RIN: 1 MΩ 0.9 to 1.1 kHz UCP+ >2 V, UCP- <-2 V |
CP State Simulation | Display range: A Nominal values: > 900 kΩ ±0.2% Display range: B Nominal values: Upper level: 4610 Ω, ±0.2% Nominal level: 2740 Ω, ±0.2% Lower level: 1870 Ω, ±0.2% Display range: C Nominal values: Upper level: 1254.2 Ω, ±0.2% Nominal level: 881.7 Ω, ±0.2% Lower level: 611.7 Ω, ±0.2% Display range: D Nominal values: Upper level: 408.3 Ω, ±0.2% Nominal level: 245.8 Ω, ±0.2% Lower level: 130.2 Ω, ±0.2% |
Fault Simulation | Display range: PE error (earth fault/PE open) Measurement range: Pass/Fail Display range: CP error E Measurement range: Pass/Fail Operational error: 0 Ω +2 Ω Display range: Diode short Measurement range: Pass/Fail Display range: Error D Measurement range: Pass/Fail |
PP Resistor Measurement Type 1 with Cable (S3, R6, R7) | Display range: 50 to 499.9 Ω, 500 to 5000 Ω Measurement range: 50 to 499.9 Ω, 500 to 5000 Ω Operational error: ±1% Nominal values: Imax charge limit: 25 A |
CP Resistor Measurement (R1) | Display range: 800 to 1200 Ω Measurement range: 800 to 1200 Ω Operational error: ±1% |
Analyzer Specifications | |
Input electrical ratings | 250 V maximum, 50/60 Hz, maximum 1 A |
EV Connector | SAE J1772 socket (type 1, SP single-phase) |
Internal Power Consumption | 3W maximum |
Environmental Conditions | |
Temperature | Operating: 14 to 104°F (-10 to 40°C) Storage: -4 to 122°F (-20 to 50°C) |
Relative Humidity | Operating: 10 to 85%, 32 to 104°F (0 to 40°C), non-condensing Storage: up to 95% |
Altitude | 9842.5' (3000 m) |
Safety | IEC 61010-1: Pollution Degree 2, IEC 61010-2-030, CAT III 300 V, Protection Class II |
Ingress Protection | IP40 |
Wireless Radio, Bluetooth 5.0 | |
Frequency Range | 2400 to 2483.5 MHz |
Output Power | <100 mW |
Electromagnetic Compatibility (EMC) | |
International | IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. |
USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. |
General Specifications | |
Battery | 4 x AA/IEC LR6 alkaline or IEC HR6 NiMH |
Dimensions | Approximately 10.35 x 4.84 x 2.48" (263 x 123 x 63 mm) without the TY1 |
Weight | Approximately 2 lbs (0.9 kg), without the TY1 connector or 3 lbs (1.4 kg) with the TY1 connector |
Click on a category to view a selection of compatible accessories with the Fluke FEV150 EV Charging Station Analyzer Kit with type 1 plug.
PE Pre-Test | |
Touch Voltage (safe range) | Display range: ≤50 V AC/DC Measurement range: ≤50 V AC/DC Operational error: -50% |
Touch Voltage (dangerous range) | Display range: >50 V AC/DC Measurement range: >50 V AC/DC Operational error: -0% |
GFCI Trip | |
Quick Trip | Display range: 30 mA, trip time limit: 0.56 seconds Measurement range: 30 mA, trip time limit: 0.56 seconds Operational error: Test current: 0 to 10% Nominal values: 100 to 253 V AC, 45 to 66 Hz |
Troubleshooting 6 mA GFCI | Display range: 3.5 mA, no trip Measurement range: 3.5 mA, no trip Operational error: Test current: -10 to 0% Nominal values: 100 to 253 V AC, 45 to 66 Hz Display range: 10 mA, trip time limit: 2.69 seconds Measurement range: 10 mA, trip time limit: 2.69 seconds Operational error: Test current: 0 to 10% Nominal values: 100 to 253 V AC, 45 to 66 Hz |
Troubleshooting 20 mA GFCI | Display range: 6 mA, no trip Measurement range: 6 mA, no trip Operational error: Test current: -10% to 0% Nominal values: 100 to 253 V AC, 45 to 66 Hz Display range: 30 mA, trip time limit: 0.56 seconds Measurement range: 30 mA, trip time limit: 0.56 seconds Operational error: Test current: 0 to 10% Nominal values: 100 to 253 V AC, 45 to 66 Hz |
Nominal Voltage | |
L1-L2/N | Display range: 0 to 280 V AC Measurement range: 0 to 253 V AC Operational error: ±(3% + 3 digits) Nominal values: 40 to 70 Hz, crest factor 2 |
Frequency | Display range: 40 to 70 Hz Measurement range: 40 to 70 Hz Operational error: ±0.20 Hz |
CP Signal Analysis | |
Voltage | Display range: -15 to 15 V Measurement range: -15 to -2 V, 2 to 15 V Operational error: ±0.5% Nominal values: RIN: 1 MΩ 0.9 to 1.1 kHz UCP+ >2 V, UCP- <-2 V |
PWM Duty Cycle | Display range: 2 to 98% Measurement range: 3 to 97% Operational error: ±5 digits Nominal values: RIN: 1 MΩ 0.9 to 1.1 kHz UCP+ >2 V, UCP- <-2 V |
Current Indication | Display range: 0 to 80 A Operational error: Based on duty cycle Nominal values: RIN: 1 MΩ 0.9 to 1.1 kHz UCP+ >2 V, UCP- <-2 V |
Frequency | Display range: 0.9 to 1.1 kHz (A, B, C, D) Measurement range: 0.9 to 1.1 kHz Operational error: 0.1% (based on voltage) Nominal values: RIN: 1 MΩ 0.9 to 1.1 kHz UCP+ >2 V, UCP- <-2 V |
CP State Indication | Display range: x1, x2 Operational error: Based on frequency Nominal values: RIN: 1 MΩ 0.9 to 1.1 kHz UCP+ >2 V, UCP- <-2 V |
CP State Simulation | Display range: A Nominal values: > 900 kΩ ±0.2% Display range: B Nominal values: Upper level: 4610 Ω, ±0.2% Nominal level: 2740 Ω, ±0.2% Lower level: 1870 Ω, ±0.2% Display range: C Nominal values: Upper level: 1254.2 Ω, ±0.2% Nominal level: 881.7 Ω, ±0.2% Lower level: 611.7 Ω, ±0.2% Display range: D Nominal values: Upper level: 408.3 Ω, ±0.2% Nominal level: 245.8 Ω, ±0.2% Lower level: 130.2 Ω, ±0.2% |
Fault Simulation | Display range: PE error (earth fault/PE open) Measurement range: Pass/Fail Display range: CP error E Measurement range: Pass/Fail Operational error: 0 Ω +2 Ω Display range: Diode short Measurement range: Pass/Fail Display range: Error D Measurement range: Pass/Fail |
PP Resistor Measurement Type 1 with Cable (S3, R6, R7) | Display range: 50 to 499.9 Ω, 500 to 5000 Ω Measurement range: 50 to 499.9 Ω, 500 to 5000 Ω Operational error: ±1% Nominal values: Imax charge limit: 25 A |
CP Resistor Measurement (R1) | Display range: 800 to 1200 Ω Measurement range: 800 to 1200 Ω Operational error: ±1% |
Analyzer Specifications | |
Input electrical ratings | 250 V maximum, 50/60 Hz, maximum 1 A |
EV Connector | SAE J1772 socket (type 1, SP single-phase) |
Internal Power Consumption | 3W maximum |
Environmental Conditions | |
Temperature | Operating: 14 to 104°F (-10 to 40°C) Storage: -4 to 122°F (-20 to 50°C) |
Relative Humidity | Operating: 10 to 85%, 32 to 104°F (0 to 40°C), non-condensing Storage: up to 95% |
Altitude | 9842.5' (3000 m) |
Safety | IEC 61010-1: Pollution Degree 2, IEC 61010-2-030, CAT III 300 V, Protection Class II |
Ingress Protection | IP40 |
Wireless Radio, Bluetooth 5.0 | |
Frequency Range | 2400 to 2483.5 MHz |
Output Power | <100 mW |
Electromagnetic Compatibility (EMC) | |
International | IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. |
USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. |
General Specifications | |
Battery | 4 x AA/IEC LR6 alkaline or IEC HR6 NiMH |
Dimensions | Approximately 10.35 x 4.84 x 2.48" (263 x 123 x 63 mm) without the TY1 |
Weight | Approximately 2 lbs (0.9 kg), without the TY1 connector or 3 lbs (1.4 kg) with the TY1 connector |
Click on a category to view a selection of compatible accessories with the Fluke FEV150 EV Charging Station Analyzer Kit with type 1 plug.