1-888-610-7664

sales@GlobalTestSupply.com

Customer Reviews

Fluke FEV150 EV Charging Station Analyzer Kit with type 1 plug and TruTest software

Model: FEV150/TY1 PRO | UPC: 195112122013

Fluke FEV150 EV Charging Station Analyzer Kit with type 1 plug and TruTest software-


Downloads: datasheet

Fluke FEV150 EV Charging Station Analyzer Kit with type 1 plug and TruTest software

Model: FEV150/TY1 PRO

Perfect for field technicians who value safety, ease of use, and portability, this EV charging station analyzer provides predetermined test plans and pass/fail indicators, allowing thorough and efficient testing without needing multiple tools. In addition, this kit comes with a type 1 plug and TruTest software.

Perfect for field technicians who value safety, ease of use, and portability, this EV charging station analyzer provides predetermined test plans and pass/fail indicators, allowing thorough and efficient testing without needing multiple tools. In addition, this kit comes with a type 1 plug and TruTest software.

Your Price $3299.99 USD
Availability 2 to 3 Weeks
Quantity

Fluke FEV150/TY1 PRO Offers

Test the safety and functionality of AC electrical vehicle charging stations with the all-in-one tool that is safe, portable, and efficient.

The FEV150 is a complete solution for safety and performance testing of AC EV charging stations with Type 1 (J1772) or Tesla-type connectors. Deliver uptime reliability with Fluke's next generation of EV Charging test solutions, designed for technicians to perform and document multiple tests safely, quickly, and efficiently without carrying multiple tools.

The FEV150 EV Charging Station Analyzer is compliant with J1772 standards.

Features

  • Provides critical protective ground testing of the station
  • Comprehensive EVSE test tool with UI to support all critical performance and safety tests of AC EV charging stations
  • Advanced functionality with Auto CP waveform analysis
  • Only tool to support all AC EVSE connectors available
  • Pass/Fail indications on all measurement results
  • GFCI testing for 6 and 20 mA GFCI circuits
  • PE (protective) earth pre-test to ensure no dangerous voltage is present
  • Visual inspection
  • GFCI trip test
  • Nominal voltage
  • Auto control pilot (CP) with waveform analysis
  • Error testing
  • Proximity pilot
  • Manual control pilot
  • Advanced GFCI test
  • Color LCD display: On-screen instructions provide an easy walkthrough of tests with a pass/fail indication on all test results
  • Easily analyze EV charging performance: Auto control pilot simulates various charging states with on-screen feedback of nominal results and waveform analysis
  • Function selection
  • PE pre-test to check if hazardous voltage is present
  • Press up/down and left/right arrow keys to select features on the display

Applications

  • Charging station safety testing
  • Charging station performance testing
  • Charging station troubleshooting/repair

Fluke FEV150/TY1 PRO Specifications

PE Pre-Test
Touch Voltage (safe range) Display range: ≤50 V AC/DC
Measurement range: ≤50 V AC/DC
Operational error: -50%
Touch Voltage (dangerous range) Display range: >50 V AC/DC
Measurement range: >50 V AC/DC
Operational error: -0%
GFCI Trip
Quick Trip Display range: 30 mA, trip time limit: 0.56 seconds
Measurement range: 30 mA, trip time limit: 0.56 seconds
Operational error: Test current: 0 to 10%
Nominal values: 100 to 253 V AC, 45 to 66 Hz
Troubleshooting 6 mA GFCI Display range: 3.5 mA, no trip
Measurement range: 3.5 mA, no trip
Operational error: Test current: -10 to 0%
Nominal values: 100 to 253 V AC, 45 to 66 Hz

Display range: 10 mA, trip time limit: 2.69 seconds
Measurement range: 10 mA, trip time limit: 2.69 seconds
Operational error: Test current: 0 to 10%
Nominal values: 100 to 253 V AC, 45 to 66 Hz
Troubleshooting 20 mA GFCI Display range: 6 mA, no trip
Measurement range: 6 mA, no trip
Operational error: Test current: -10% to 0%
Nominal values: 100 to 253 V AC, 45 to 66 Hz

Display range: 30 mA, trip time limit: 0.56 seconds
Measurement range: 30 mA, trip time limit: 0.56 seconds
Operational error: Test current: 0 to 10%
Nominal values: 100 to 253 V AC, 45 to 66 Hz
Nominal Voltage
L1-L2/N Display range: 0 to 280 V AC
Measurement range: 0 to 253 V AC
Operational error: ±(3% + 3 digits)
Nominal values: 40 to 70 Hz, crest factor 2
Frequency Display range: 40 to 70 Hz
Measurement range: 40 to 70 Hz
Operational error: ±0.20 Hz
CP Signal Analysis
Voltage Display range: -15 to 15 V
Measurement range: -15 to -2 V, 2 to 15 V
Operational error: ±0.5%
Nominal values:
RIN: 1 MΩ
0.9 to 1.1 kHz
UCP+ >2 V, UCP- <-2 V
PWM Duty Cycle Display range: 2 to 98%
Measurement range: 3 to 97%
Operational error: ±5 digits
Nominal values:
RIN: 1 MΩ
0.9 to 1.1 kHz
UCP+ >2 V, UCP- <-2 V
Current Indication Display range: 0 to 80 A
Operational error: Based on duty cycle
Nominal values:
RIN: 1 MΩ
0.9 to 1.1 kHz
UCP+ >2 V, UCP- <-2 V
Frequency Display range: 0.9 to 1.1 kHz (A, B, C, D)
Measurement range: 0.9 to 1.1 kHz
Operational error: 0.1% (based on voltage)
Nominal values:
RIN: 1 MΩ
0.9 to 1.1 kHz
UCP+ >2 V, UCP- <-2 V
CP State Indication Display range: x1, x2
Operational error: Based on frequency
Nominal values:
RIN: 1 MΩ
0.9 to 1.1 kHz
UCP+ >2 V, UCP- <-2 V
CP State Simulation Display range: A
Nominal values: > 900 kΩ ±0.2%

Display range: B
Nominal values:
Upper level: 4610 Ω, ±0.2%
Nominal level: 2740 Ω, ±0.2%
Lower level: 1870 Ω, ±0.2%

Display range: C
Nominal values:
Upper level: 1254.2 Ω, ±0.2%
Nominal level: 881.7 Ω, ±0.2%
Lower level: 611.7 Ω, ±0.2%

Display range: D
Nominal values:
Upper level: 408.3 Ω, ±0.2%
Nominal level: 245.8 Ω, ±0.2%
Lower level: 130.2 Ω, ±0.2%
Fault Simulation Display range: PE error (earth fault/PE open)
Measurement range: Pass/Fail

Display range: CP error E
Measurement range: Pass/Fail
Operational error: 0 Ω +2 Ω

Display range: Diode short
Measurement range: Pass/Fail

Display range: Error D
Measurement range: Pass/Fail
PP Resistor Measurement Type 1 with Cable (S3, R6, R7) Display range: 50 to 499.9 Ω, 500 to 5000 Ω
Measurement range: 50 to 499.9 Ω, 500 to 5000 Ω
Operational error: ±1%
Nominal values: Imax charge limit: 25 A
CP Resistor Measurement (R1) Display range: 800 to 1200 Ω
Measurement range: 800 to 1200 Ω
Operational error: ±1%
Analyzer Specifications
Input electrical ratings 250 V maximum, 50/60 Hz, maximum 1 A
EV Connector SAE J1772 socket (type 1, SP single-phase)
Internal Power Consumption 3W maximum
Environmental Conditions
Temperature Operating: 14 to 104°F (-10 to 40°C)
Storage: -4 to 122°F (-20 to 50°C)
Relative Humidity Operating: 10 to 85%, 32 to 104°F (0 to 40°C), non-condensing
Storage: up to 95%
Altitude 9842.5' (3000 m)
Safety IEC 61010-1: Pollution Degree 2, IEC 61010-2-030, CAT III 300 V, Protection Class II
Ingress Protection IP40
Wireless Radio, Bluetooth 5.0
Frequency Range 2400 to 2483.5 MHz
Output Power <100 mW
Electromagnetic Compatibility (EMC)
International IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
General Specifications
Battery 4 x AA/IEC LR6 alkaline or IEC HR6 NiMH
Dimensions Approximately 10.35 x 4.84 x 2.48" (263 x 123 x 63 mm) without the TY1
Weight Approximately 2 lbs (0.9 kg), without the TY1 connector or 3 lbs (1.4 kg) with the TY1 connector
Click here for complete specifications on the Fluke FEV150/TY1 PRO

What's included with the Fluke FEV150/TY1 PRO

  • Charging Station Analyzer
  • Type 1 Plug
  • Magnetic Hanger
  • Soft Carrying Case
  • Fluke TruTest Software

Click on a category to view a selection of compatible accessories with the Fluke FEV150 EV Charging Station Analyzer Kit with type 1 plug and TruTest software.

Fluke FEV-CON-TSL Tesla Type Connector and Cable for the FEV100 series FEV-CON-TSL
Compatible with the FEV100 electric vehicle charging station adapter kits, this Tesla-type connector is ideal for level 1 and 2 AC charging stations. In addition, it tests the function and safety of charging equipment for electric vehicles.




Fluke FEV-CON/TY1 Type 1 Connector and Cable for the FEV100 series FEV-CON/TY1
This type 1 connector is for use with the FEV100 Electric Vehicle Charging Station Adapter.




Ask a question about Fluke FEV150 EV Charging Station Analyzer Kit with type 1 plug and TruTest software

Customer Reviews for the Fluke FEV150/TY1 PRO

Fluke FEV150/TY1 PRO Offers

Test the safety and functionality of AC electrical vehicle charging stations with the all-in-one tool that is safe, portable, and efficient.

The FEV150 is a complete solution for safety and performance testing of AC EV charging stations with Type 1 (J1772) or Tesla-type connectors. Deliver uptime reliability with Fluke's next generation of EV Charging test solutions, designed for technicians to perform and document multiple tests safely, quickly, and efficiently without carrying multiple tools.

The FEV150 EV Charging Station Analyzer is compliant with J1772 standards.

Features

  • Provides critical protective ground testing of the station
  • Comprehensive EVSE test tool with UI to support all critical performance and safety tests of AC EV charging stations
  • Advanced functionality with Auto CP waveform analysis
  • Only tool to support all AC EVSE connectors available
  • Pass/Fail indications on all measurement results
  • GFCI testing for 6 and 20 mA GFCI circuits
  • PE (protective) earth pre-test to ensure no dangerous voltage is present
  • Visual inspection
  • GFCI trip test
  • Nominal voltage
  • Auto control pilot (CP) with waveform analysis
  • Error testing
  • Proximity pilot
  • Manual control pilot
  • Advanced GFCI test
  • Color LCD display: On-screen instructions provide an easy walkthrough of tests with a pass/fail indication on all test results
  • Easily analyze EV charging performance: Auto control pilot simulates various charging states with on-screen feedback of nominal results and waveform analysis
  • Function selection
  • PE pre-test to check if hazardous voltage is present
  • Press up/down and left/right arrow keys to select features on the display

Applications

  • Charging station safety testing
  • Charging station performance testing
  • Charging station troubleshooting/repair

Fluke FEV150/TY1 PRO Specifications

PE Pre-Test
Touch Voltage (safe range) Display range: ≤50 V AC/DC
Measurement range: ≤50 V AC/DC
Operational error: -50%
Touch Voltage (dangerous range) Display range: >50 V AC/DC
Measurement range: >50 V AC/DC
Operational error: -0%
GFCI Trip
Quick Trip Display range: 30 mA, trip time limit: 0.56 seconds
Measurement range: 30 mA, trip time limit: 0.56 seconds
Operational error: Test current: 0 to 10%
Nominal values: 100 to 253 V AC, 45 to 66 Hz
Troubleshooting 6 mA GFCI Display range: 3.5 mA, no trip
Measurement range: 3.5 mA, no trip
Operational error: Test current: -10 to 0%
Nominal values: 100 to 253 V AC, 45 to 66 Hz

Display range: 10 mA, trip time limit: 2.69 seconds
Measurement range: 10 mA, trip time limit: 2.69 seconds
Operational error: Test current: 0 to 10%
Nominal values: 100 to 253 V AC, 45 to 66 Hz
Troubleshooting 20 mA GFCI Display range: 6 mA, no trip
Measurement range: 6 mA, no trip
Operational error: Test current: -10% to 0%
Nominal values: 100 to 253 V AC, 45 to 66 Hz

Display range: 30 mA, trip time limit: 0.56 seconds
Measurement range: 30 mA, trip time limit: 0.56 seconds
Operational error: Test current: 0 to 10%
Nominal values: 100 to 253 V AC, 45 to 66 Hz
Nominal Voltage
L1-L2/N Display range: 0 to 280 V AC
Measurement range: 0 to 253 V AC
Operational error: ±(3% + 3 digits)
Nominal values: 40 to 70 Hz, crest factor 2
Frequency Display range: 40 to 70 Hz
Measurement range: 40 to 70 Hz
Operational error: ±0.20 Hz
CP Signal Analysis
Voltage Display range: -15 to 15 V
Measurement range: -15 to -2 V, 2 to 15 V
Operational error: ±0.5%
Nominal values:
RIN: 1 MΩ
0.9 to 1.1 kHz
UCP+ >2 V, UCP- <-2 V
PWM Duty Cycle Display range: 2 to 98%
Measurement range: 3 to 97%
Operational error: ±5 digits
Nominal values:
RIN: 1 MΩ
0.9 to 1.1 kHz
UCP+ >2 V, UCP- <-2 V
Current Indication Display range: 0 to 80 A
Operational error: Based on duty cycle
Nominal values:
RIN: 1 MΩ
0.9 to 1.1 kHz
UCP+ >2 V, UCP- <-2 V
Frequency Display range: 0.9 to 1.1 kHz (A, B, C, D)
Measurement range: 0.9 to 1.1 kHz
Operational error: 0.1% (based on voltage)
Nominal values:
RIN: 1 MΩ
0.9 to 1.1 kHz
UCP+ >2 V, UCP- <-2 V
CP State Indication Display range: x1, x2
Operational error: Based on frequency
Nominal values:
RIN: 1 MΩ
0.9 to 1.1 kHz
UCP+ >2 V, UCP- <-2 V
CP State Simulation Display range: A
Nominal values: > 900 kΩ ±0.2%

Display range: B
Nominal values:
Upper level: 4610 Ω, ±0.2%
Nominal level: 2740 Ω, ±0.2%
Lower level: 1870 Ω, ±0.2%

Display range: C
Nominal values:
Upper level: 1254.2 Ω, ±0.2%
Nominal level: 881.7 Ω, ±0.2%
Lower level: 611.7 Ω, ±0.2%

Display range: D
Nominal values:
Upper level: 408.3 Ω, ±0.2%
Nominal level: 245.8 Ω, ±0.2%
Lower level: 130.2 Ω, ±0.2%
Fault Simulation Display range: PE error (earth fault/PE open)
Measurement range: Pass/Fail

Display range: CP error E
Measurement range: Pass/Fail
Operational error: 0 Ω +2 Ω

Display range: Diode short
Measurement range: Pass/Fail

Display range: Error D
Measurement range: Pass/Fail
PP Resistor Measurement Type 1 with Cable (S3, R6, R7) Display range: 50 to 499.9 Ω, 500 to 5000 Ω
Measurement range: 50 to 499.9 Ω, 500 to 5000 Ω
Operational error: ±1%
Nominal values: Imax charge limit: 25 A
CP Resistor Measurement (R1) Display range: 800 to 1200 Ω
Measurement range: 800 to 1200 Ω
Operational error: ±1%
Analyzer Specifications
Input electrical ratings 250 V maximum, 50/60 Hz, maximum 1 A
EV Connector SAE J1772 socket (type 1, SP single-phase)
Internal Power Consumption 3W maximum
Environmental Conditions
Temperature Operating: 14 to 104°F (-10 to 40°C)
Storage: -4 to 122°F (-20 to 50°C)
Relative Humidity Operating: 10 to 85%, 32 to 104°F (0 to 40°C), non-condensing
Storage: up to 95%
Altitude 9842.5' (3000 m)
Safety IEC 61010-1: Pollution Degree 2, IEC 61010-2-030, CAT III 300 V, Protection Class II
Ingress Protection IP40
Wireless Radio, Bluetooth 5.0
Frequency Range 2400 to 2483.5 MHz
Output Power <100 mW
Electromagnetic Compatibility (EMC)
International IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
General Specifications
Battery 4 x AA/IEC LR6 alkaline or IEC HR6 NiMH
Dimensions Approximately 10.35 x 4.84 x 2.48" (263 x 123 x 63 mm) without the TY1
Weight Approximately 2 lbs (0.9 kg), without the TY1 connector or 3 lbs (1.4 kg) with the TY1 connector
Click here for complete specifications on the Fluke FEV150/TY1 PRO

What's included with the Fluke FEV150/TY1 PRO

  • Charging Station Analyzer
  • Type 1 Plug
  • Magnetic Hanger
  • Soft Carrying Case
  • Fluke TruTest Software

Click on a category to view a selection of compatible accessories with the Fluke FEV150 EV Charging Station Analyzer Kit with type 1 plug and TruTest software.

Fluke FEV-CON-TSL Tesla Type Connector and Cable for the FEV100 series FEV-CON-TSL
Compatible with the FEV100 electric vehicle charging station adapter kits, this Tesla-type connector is ideal for level 1 and 2 AC charging stations. In addition, it tests the function and safety of charging equipment for electric vehicles.




Fluke FEV-CON/TY1 Type 1 Connector and Cable for the FEV100 series FEV-CON/TY1
This type 1 connector is for use with the FEV100 Electric Vehicle Charging Station Adapter.




Ask a question about Fluke FEV150 EV Charging Station Analyzer Kit with type 1 plug and TruTest software

Customer Reviews for the Fluke FEV150/TY1 PRO

More Fluke Products